SolarPairing / Works, closed loop

Deye 5-16 kW hybrid inverters (single- and three-phase) × Hubble Energy AM-2 / AM-4 / AM-5 / AM-10 / AM-10+ / AM-16+ / Blade / X101

Hubble documents a closed-loop CAN connection between its listed 48 V battery range and Deye 5-16 kW single- and three-phase hybrid inverters. The documented arrangement connects the master battery CAN port to BMS_CAN and requires the Lithium battery type, current limit appropriate to the installed battery bank and current inverter firmware. Confirm the exact Deye model, port generation, battery master address and wiring diagram before installation.

Status

Works, closed loop

Protocol

CAN (500 kbit/s)

Last verified

2026-10-02

01 / About this pairing

Hubble documents a closed-loop CAN connection between its listed 48 V battery range and Deye 5-16 kW single- and three-phase hybrid inverters. The documented arrangement connects the master battery CAN port to BMS_CAN and requires the Lithium battery type, current limit appropriate to the installed battery bank and current inverter firmware. Confirm the exact Deye model, port generation, battery master address and wiring diagram before installation.

02 / Source

https://www.hubbleenergy.com/deye